Rectangularity and surface flatness.
Tile floor flatness tolerances.
The standard simply defines the required flatness of a concrete subfloor.
Many manufacturers of wood flooring require that the variation in floor flatness be no more than 3 16 in 10 and 1 8 in 6.
F numbers provide architects and contractors a method of determining the flatness and levelness of a concrete floor slab.
On a large floor the surface should also be flat within 15mm of the datum or as per the architects specified tolerance.
Areas within 1 5 meters of walls columns or.
I don t know the equivalent wall building tolerance.
In the case of surface flatness a straight edge on the diagonal can be used to measure centre and edge curvature and warpage.
The subfloor or underfloor as i like to call it shall not deviate more than 3 16 of an inch in ten feet photo 1 shows a ten straight edge.
3 these f numbers use dimensionless symbols to designate both flatness and levelness and are designated as.
Just like ceramic tile wood and resilient flooring require a high degree of flatness that can easily be achieved using a cementitious slu.
B installation tolerances for tiles after they are installed this is described in as 3958 1 1991 ceramic tiles part 1.
They are calculated using the standards set forth in astm e1155 which is the standard test method for determining f f floor flatness and f l floor levelness numbers the american concrete institute indicates acceptable ranges for flatness and levelness in aci 302 1 guide.
For many internal ground floors the most suitable tolerances to be worked to are free movement classifications fm as defined in tr34 by the concrete society a floor is classified as free movement if it can be driven around freely by vehicles such as forklifts without too many obstacles such as columns or walls.
The ansi a108 02 standards say that acceptable lippage for floor tiles with a grout joint width of 1 16 to less than 1 4 is 1 32 plus the allowable inherent warpage of the tile.
The same tests apply for the flatness of a floor substrate and floor tiling.
For over 50 years concrete floor surface tolerances were typically measured and described by the maximum gap allowed under a 3000 mm 10 foot long straightedge.
Floor levelness tolerances evaluate the effect of different construction methods on resulting floor surface flatness and levelness and investigate the curling and deflection of floor surfaces.
If the grout joint width is 1 4 or greater then the allowable warpage is 1 16 plus the allowable inherent warpage of the tile.
When measured as described in astm c 485 the warpage of each tile in the sample shall not exceed 1 0 percent along any edge nor 0 75 percent on either diagonal.
For a paver tile commonly used on floors the allowable warpage is defined as follows.
Guide to the installation of ceramic tiles on page 53.
The following appendix is a discussion on floor flatness measurement methods and is provided for general information only 01 history of flatness and levelness measurement of concrete substrate surfaces to receive flooring.