Finally a class three listing requires the material to be resistant to 57 54.
Ul listing for 1 hour concrete masonry wall.
Code requirements for determining fire resistance of concrete and masonry construction assemblies aci 216 1 07 tms 0216 07.
3 1 4 lwc fluted.
Conducted in accordance with ansi ul 1479.
J for concrete or masonry walls less than or equal to 8 inches thick.
13 mm a 1 in.
Westbrook block prides itself on manufacturing ul cmu that can be integrated into the design assemblies listed below.
A class two listing requires the material to be resistant to a 20 foot water pressure head.
Cable pathway penetrations through concrete floor concrete wall or block wall simplified drawing 8 25 15 1 hr 2 hr 1 hr 2 hr cable pathway penetrations through gypsum wall simplified drawing 11 12 15 dwg pdf low voltage penetrations for communication systems applications comprehensive drawing 8 25 15 dwg pdf fire resistive curtain wall.
Cfs sp wb water based acrylic sealant spray mineral wool show all.
As the global safety science leader ul helps companies to demonstrate safety enhance sustainability strengthen security deliver quality manage risk and achieve regulatory compliance.
American concrete institute and the masonry society 2007.
D798 res nwc mk6gf.
D798 res nwc z106h non load restricted.
D798 unres lwc z106hy.
Standard for fire tests of building construction and materials ul 263.
U901 x902 u904 u905 u906 u910 u912 u913 u914 underwriters laboratories inc.
D798 res nwc all.
These wall assembly files are used for planning and estimation purposes for many ul wall types such as fire rated wall assemblies.
Download english 104 kb hw d 0259.
Recognized method to the underwriters laboratory ul listing service.
Ul is an independent third party product safety testing and certification organization.
The equivalent thickness of concrete masonry assemblies t ea shall be computed as the sum thicknessof the equivalent thickness average solid thickness as shown in figure 1 of the concrete masonry unit t e plus the equivalent thickness of finishes t ef.
D798 unres nwc all.
For example for an 8 in.
Usg provides resources here for our ul wall assemblies for seamless integration into any construction project.
Gypsum wall to concrete over fluted metal deck with structural steel beams or bar joists penetrating wall top of wall max.
51 mm thickness can be used.
25 mm thickness measured perpendicular to the face of the wall of ceramic fiber in the joint can be used in walls with fire resistance ratings up to 3 hours while a 2 in.